Refrigerant Pressure Sensor Repair

Is Your A/C Acting Up Don't Wait Until It Fails Completely!

A faulty refrigerant pressure sensor can lead to:

  • Inconsistent A/C performance
  • Complete system shutdown
  • Compressor damage
  • Higher fuel consumption

Trust our ASE-certified mechanics to diagnose and repair your vehicle's refrigerant pressure sensor right the first time.

Industry-leading24-month/24,000-mile warranty

Servicingall makes and models

Same-day service available

Professional diagnostic equipment

Refrigerant Pressure Sensor/Switch Repair Costs

Low-Pressure Switch Replacement
Typical labor time: 1-1.5 hours
Parts cost: $45-85
Total estimated cost: $170-275

High-Pressure Switch Replacement
Typical labor time: 1-1.5 hours
Parts cost: $55-95
Total estimated cost: $180-285

Dual-Pressure Switch Replacement
Typical labor time: 1.5-2 hours
Parts cost: $85-150
Total estimated cost: $275-400

Note: These prices are estimates and may vary based on:

  • Vehicle make and model
  • Switch accessibility
  • System diagnosis time
  • Required refrigerant recharge

Additional Costs to Consider:

  • Refrigerant recharge: $75-150
  • System diagnosis: $125 (one hour)
  • Leak testing if required: $95

All repairs include basic system testing and verification of proper operation. Our standard labor rate is $125/hour.

Refrigerant Pressure Sensor/Switch Repair Guide

Low Pressure Switch Repair

Common Symptoms:AC not cooling, system cycling on and off frequently, or compressor not engaging

Repair Steps:

  1. Verify refrigerant pressure readings using manifold gauges
  2. Locate the low pressure switch (typically on the suction line near the compressor)
  3. Disconnect the electrical connector from the switch
  4. Test switch operation with a multimeter to confirm failure
  5. Remove the old switch using appropriate wrenches
  6. Install new switch with new o-rings or seals
  7. Reconnect electrical connections
  8. Verify proper system operation

High Pressure Switch Repair

Common Symptoms:System shutting down unexpectedly, compressor cutting out under load, or no cooling in hot weather

Repair Steps:

  1. Check refrigerant pressure readings to confirm overcharge or restriction
  2. Locate the high pressure switch (typically on the discharge line or near the condenser)
  3. Disconnect electrical connections
  4. Test switch functionality with multimeter
  5. Remove failed switch carefully to prevent refrigerant loss
  6. Install replacement switch with new seals
  7. Reconnect electrical connections
  8. Test system operation under load

Binary Pressure Switch Repair

Common Symptoms:Inconsistent cooling, system pressure fluctuations, or compressor cycling issues

Repair Steps:

  1. Connect manifold gauges to verify both high and low side pressures
  2. Locate binary switch (usually near the accumulator or receiver drier)
  3. Remove electrical connections
  4. Test switch operation with multimeter
  5. Recover refrigerant if necessary
  6. Remove old switch
  7. Install new binary switch with fresh seals
  8. Reconnect electrical connections
  9. Evacuate and recharge system if refrigerant was recovered
  10. Verify proper operation across all pressure ranges

Important Notes:

  • Always recover refrigerant properly before opening the system
  • Use only OEM or equivalent quality replacement parts
  • Replace o-rings and seals with each switch replacement
  • Verify proper torque specifications when installing new switches
  • Check for proper system charge after repairs

Note: These repairs should only be performed by qualified HVAC technicians with proper certification and equipment.

Understanding Refrigerant Pressure Sensors and Switches

refrigerant-pressure-sensor-switch-.webp

Low-Pressure Switch (LPS)

TheLow-Pressure Switchis a safety device that monitors the suction pressure (low-pressure side) of the refrigeration system. It protects the compressor by:

  • Shutting down the system if refrigerant pressure drops too low
  • Preventing compressor damage from insufficient oil return
  • Detecting refrigerant leaks or restrictions in the system

High-Pressure Switch (HPS)

TheHigh-Pressure Switchmonitors the discharge pressure (high-pressure side) of the system. This critical safety component:

  • Prevents system damage from excessive pressure
  • Protects against condenser fan failures
  • Shuts down the system if pressure exceeds safe limits

Oil Pressure Switch (OPS)

TheOil Pressure Switchmonitors the differential pressure between the oil pump discharge and crankcase pressure. This switch:

  • Ensures proper oil circulation for compressor lubrication
  • Prevents compressor damage from inadequate oil pressure
  • Shuts down the system if oil pressure falls below safe levels

Pressure Transducer

APressure Transduceris an electronic sensor that provides continuous pressure monitoring. Unlike mechanical switches, it:

  • Provides real-time pressure readings
  • Enables precise system control
  • Allows for data logging and trend analysis
  • Can interface with building automation systems

Dual Pressure Switch

TheDual Pressure Switchcombines both high and low-pressure monitoring in a single unit. This device:

  • Saves space and reduces installation costs
  • Provides comprehensive pressure protection
  • Simplifies system wiring and maintenance

Note: Proper selection and installation of pressure switches is crucial for system safety and efficiency. Always consult with a qualified HVAC professional for specific applications.

Common Failure Symptoms of Refrigerant Pressure Sensors (RPS)

Understanding Refrigerant Pressure Sensor/Switch Failures

Low-Pressure Switch

Signs of Failure:

  • System short cycling (turning on and off frequently)
  • AC not cooling properly
  • Compressor fails to start
  • Frozen evaporator coil
  • Error codes on thermostat or control board

Service Schedule:

Typically inspected during annual maintenance. No regular replacement schedule, but should be tested every 2-3 years for proper operation.

High-Pressure Switch

Signs of Failure:

  • System repeatedly shuts down
  • Unusual noises from outdoor unit
  • Reduced cooling performance
  • Compressor overheating
  • System lockout requiring manual reset

Service Schedule:

Should be inspected annually during routine maintenance. Testing recommended every 2-3 years. Replace if any signs of wear or malfunction are detected.

Discharge Pressure Switch

Signs of Failure:

  • Inconsistent system operation
  • Higher than normal energy bills
  • Compressor strain or damage
  • Irregular pressure readings

Service Schedule:

Annual inspection during maintenance. Replace every 5-7 years or when showing signs of wear.

Important Note: These are general guidelines. Actual service intervals may vary based on:

  • System usage
  • Environmental conditions
  • Manufacturer recommendations
  • Local climate

Regular professional maintenance is key to ensuring proper operation of all pressure switches and extending system life.

How It Works

  • Get a quote online or set-up a time to have your vehicle looked at.
  • Pick time slots that work for you, easily, online.
  • We will confirm appointments and send reminders.
  • Our mechanics bring everything that is needed to you.
  • All you have to do is provided a safe area for the work to be performed.

What we need from you

  • A safe place to work on your vehicle
  • No working on the side of busy roads
  • No working on unstable or steep surfaces.
  • We do not perform repairs during severe weather.
  • Authorization from a property owner or management.
  • Repair work done in a parking lot or at your  requires permission.
  • We do not do repairs in areas restricted by law.

Common Questions

Service Area

Our primary service area is greater Grand Rapids and includes Comstock Park, East Grand Rapids, Grandville,  Kentwood, Walker, and Wyoming

Our secondary service area is provided by our Belding location and includes: Belding, Greenville, Ionia and the sorrounding areas.

Contact us if you have any questions about where we provide services.

What our customers say: