P0429Catalyst Heater Control Circuit (Bank 1)
An electrical fault has been detected in the control circuit for the Bank 1 electrically heated catalyst.
Definition
Common causes
- Failed catalyst heater relay
- Blown fuse in the heater power feed
- Open or shorted wiring in the control or feedback circuit
- Open heater element pulling the feedback out of range
- Failed PCM driver stage (rare)
Common misdiagnoses
- Catalytic converter assembly replaced when only the relay or a fuse has failed
- PCM replaced before the relay and wiring are tested
- Oxygen sensors replaced based on the catalyst-range code alone
Troubleshooting steps
1.Check the fuse and relay first
Verify the heater fuse is intact and swap or bench-test the relay; these are the cheapest and most common failures in this circuit.
2.Command the heater with a scan tool
Use bidirectional controls (or a cold start) to activate the heater and listen or meter for the relay clicking and the circuit going live.
3.Test the control circuit wiring
Confirm the PCM's control signal reaches the relay coil and that the relay output delivers battery voltage to the heater connector.
4.Measure the heater element
Check resistance across the heater terminals; an open element can set this code by disturbing the feedback the PCM expects.
5.Inspect grounds and connectors
A corroded ground for the high-current heater circuit causes voltage-drop faults; verify less than 0.2 V drop on the ground side under load.