P0545Exhaust Gas Temperature Sensor Circuit Low (Bank 1, Sensor 1)
The first exhaust gas temperature sensor on bank 1 is reading a lower circuit voltage than possible, usually from a short to ground.
Definition
Common causes
- EGT sensor shorted internally after thermal cycling
- Sensor harness melted against the exhaust and shorted to ground
- Chafed wiring where the pigtail passes brackets or heat shields
- Moisture intrusion shorting the connector
- Signal and return wires shorted together
- ECM input fault (rare)
Common misdiagnoses
- DPF replaced for soot loading that the inhibited regens caused
- A different EGT sensor replaced due to position-numbering confusion
- Turbocharger
- Exhaust back-pressure sensor
Troubleshooting steps
1.Confirm the pegged reading
Check the bank 1 sensor 1 EGT PID cold; a reading stuck at an extreme while other EGT sensors read ambient confirms a circuit fault, not a real temperature.
2.Unplug the sensor and watch the PID
If the reading swings to the opposite extreme with the connector open, the harness and ECM are intact and the sensor is shorted.
3.Hunt the harness short if it stays pegged
With the sensor and ECM disconnected, ohm the signal wire to chassis ground; continuity confirms melted or chafed wiring to locate along the exhaust routing.
4.Inspect for heat damage
Look specifically where the pigtail nears the manifold, turbo, or downpipe for glazed, brittle insulation and repair with high-temperature sleeving.
5.Replace the sensor and verify
Fit a new EGT sensor torqued to spec, clear codes, and confirm the PID reads ambient cold and climbs normally on a test drive so regeneration is re-enabled.