P0618Alternative Fuel Control Module KAM Error
The alternative fuel (CNG/LPG) control module has detected a failure in its keep-alive memory (KAM), so stored adaptive data and settings are being lost or corrupted.
Definition
Common causes
- Interrupted keep-alive power feed to the alternative fuel module (blown fuse, corroded connector, loose battery terminal)
- Recent battery disconnect or deep discharge combined with a marginal module memory circuit
- Internal failure of the alternative fuel control module's memory circuitry
- Corrupted or failed software update/reflash of the module
- Water intrusion or corrosion at the module connector causing intermittent power/ground loss
- Voltage spikes from jump-starting or charging system faults corrupting stored memory
Common misdiagnoses
- Replacing the alternative fuel injectors or regulator when the fault is module memory power
- Replacing the vehicle battery when the module's keep-alive fuse or wiring is the problem
- Replacing the main ECM/PCM instead of the separate alternative fuel control module
- Condemning the module itself when a corroded ground or B+ feed is causing the memory loss
Troubleshooting steps
1.Verify battery and charging system health
Confirm resting battery voltage above 12.4 V and charging voltage of roughly 13.5-14.8 V, since low or spiking system voltage can corrupt keep-alive memory.
2.Check the module's keep-alive power circuit
With the key off, back-probe the constant battery feed at the alternative fuel module and confirm battery voltage with no more than 0.1-0.2 V drop; inspect the fuse and connector for corrosion.
3.Test the module grounds
Perform a voltage-drop test on each module ground with the circuit loaded; more than 0.1 V drop indicates a poor ground that must be cleaned and re-secured.
4.Clear the code and retest
Clear KAM, complete a full drive cycle including several key-off soak periods, and rescan; if P0618 returns with good power and ground, the module memory is failing.
5.Update or reflash the module
Check for manufacturer software updates addressing memory errors and reflash the alternative fuel module with the OEM tool before condemning hardware.
6.Replace and configure the module if the fault persists
Install a replacement alternative fuel control module and complete any required programming/relearn procedures per the service information.